Connecting to Power

The procedure below describes how to connect the device to the AC power supply. You can install up to two Power Supply modules (Power 1 and Power 2) for power redundancy. For installing the Power Supply modules in the chassis, see Power Supply Module.

Units must be connected (by service personnel) to a socket-outlet with a protective earthing connection.
Use only the AC power cord supplied with the device.
When using only one Power Supply module, the second AC power socket on the rear panel is covered by a plastic sticker. Please do not remove the sticker and connect anything to this power socket. Remove the sticker only when two Power Supply modules are used.

(French) Avertissements:

L’appareil doit être branché à une prise murale à condition qu’elle soit mise à la masse.
Utilisez uniquement le cordon AC fourni avec l’appareil.

(Japanese) ご注意

本製品に添付の電源ケーブルは、Mediant 1000B Gateway and E-SBC に専用設計されているため、汎用性がありません. 本電源ケーブルを他の機器に使用されないよう、ご注意ください.

For dual power supply:

Connect each Power Supply module to a different AC supply circuit.
The two AC power sources must have the same ground potential.
Configure the device to send an SNMP alarm (acPowerSupplyAlarm) upon a failure or removal of any of the installed Power Supply modules. For enabling this functionality, use the [Mediant1000DualPowerSupplySupported] parameter. For more information, refer to the User's Manual.
To connect the device to the power supply:
On the device's rear panel, connect the left (active) 100-240V~50-60 Hz power socket to a standard electrical outlet using the supplied AC power cord.

Connecting to AC Power Supply

When the device receives powers, the POWER LED on the front panel of the Power Supply module is lit green. If the LED is off, a power supply problem may be present.